7.A confirmation screen appears.
Press <M> to keep existing data on the first disk. If you choose this option, data on the first disk will be mirrored on the second disk that you will add to the volume later. Make sure the data you want to mirror is on the first disk.
Press <D> to overwrite any data and create the new IM array.
LSI Logic Config Utility | v6.08.05.00 (2006.08.02) |
Create New Array Type |
|
M - Keep existing data, migrate to an IM array.
Synchronization of disk will occur.
D- Overwrite existing data, create a new IM array. ALL DATA on ALL disk in the array will be DELETED!! No Synchronization performed.
|
|
|
Esc = Exit Menu | F1/Shift+1 = | Help |
Space/+/- = Select disk for array | or hot spare C = Create array | |
|
|
|
8.Repeat steps 5 and 6 to add the second disk to the volume.
9.When done, press <C> to create the array, then select Save changes then exit this menu.
Create and save new array?
Cancel Exit
Save changes then exit this menu
Discard changes then exit this menu
Exit the Configuration Utility and Reboot
10. The utility creates the array.
LSI Logic Config Utility | v6.08.05.00 (2006.08.02) |
|
|
Processing...may take up 1 minute
Creating RAID array
Chapter 5: RAID configuration |