Allows you to select the memory branch mode.
Configuration options: [Sequential] [Interleave] [Single channel 0]
Branch 0 Rank Interleave [4:1]Allows you to select the Branch 0 Rank Interleave. This item does not appear when the Memory Branch Mode is set to [Sequential].
Configuration options: [1:1] [2:1] [4:1]
Branch 0 Rank Sparing [Disabled]Allows you to enable or disable the Branch 0 rank/DIMM Sparing feature. This item does not appear when the Memory Branch Mode is set to [Sequential]. Configuration options: [Disabled] [Enabled]
Enhanced x8 Detection [Enabled]Allows you to enable or disable the enhanced x8 DRAM UC error detection. Configuration options: [Disabled] [Enabled]
Force ITK Config Clocking [Disabled]Allows you to enable or disable the FBD configuration for ITK test suite. Configuration options: [Disabled] [Enabled]
FBDIMM(s) Thermal Throttling [Closed Loop]Allows you to disable or set the thermal throttling control.
Configuration options: [Open Loop] [Closed Loop] [ASUS MemCool FAN] [Disabled]
Set this item to [ASUS MemCool FAN] for a better fan management.
Open Loop Type [User Define]Allows you to select the Open Loop Type.
Configuration options: [Best Performance] [Best Acoustic] [User Define]
The following items only appear when you set the Open Loop Type to [User Define].
Environment Temperature [25 ºC]Allows you to select the Environment Temperature value.
Configuration options: [20 ºC]~[40 ºC]
Temperature Rise [25 ºC]Allows you to select the Temperature Rise value.
Configuration options: [10 ºC]~[30 ºC]
FBDIMM(s) Air Flow [2.0]Allows yout to select the Air Flow value.
Configuration options: [1.0] [1.5]~[4.5] [5.0]
Chapter 4: BIOS setup |