ATTO Technology 2400C/R/D, 2370E ATTO FibreBridge 2400R/D, Dimensions, Cooling and airflow, Power

Models: 2400C/R/D 2390C/R/D 2370E

1 51
Download 51 pages 36.41 Kb
Page 14
Image 14
1.4 ATTO FibreBridge 2400R/D

1.4 ATTO FibreBridge 2400R/D

The ATTO FibreBridge 2400R/D is a high performance bridge adding 4-Gigabit Fibre Channel connectivity to legacy SCSI storage devices.

The FibreBridge 2400R/D is available in an industry- standard 1U form factor for easy integration into racks.

Default values are appropriate for most applications. Refer to Configuring the FibreBridge on page 15 for more information.

Manual background WARNING

Risk of explosion if the battery is removed and/or replaced by an incorrect type. Dispose of used batteries in accordance with your local environmental regulations.

Dimensions

Width: 17 inches

Length: 11 inches

Height: 1.7 inches (1U)

Weight: approximately 10 pounds

Cooling and airflow

Operating temperature: 0-40 °C external

Humidity: 10-90% non-condensing

Air enters from the front and is exhausted out the connector side. Ambient air near the inlets should not exceed 40°C. The unit automatically stops operation if the temperature goes beyond this threshold.

CAUTION

Do not block the enclosure’s vents. The FibreBridge does not allow data transfer if overheating occurs.

Power

The power supply circuit is permanently mounted within the enclosure and is not hot swappable. It has one standard IEC320 power receptacle and switch.

The universal power supply provides power for the bridge board and cooling fan.

The power requirements of the ATTO FibreBridge 2400R plus the power draw of the other equipment in the rack must not overload the supply circuit and/or wiring of the rack.

Input voltage: 100-240 VAC; 1.7-.7A; 50- 60Hz.

Battery-backed event log SRAM & Real-Time- Clock: A rechargeable Lithium ion battery cell holds the memory in a 512KB SRAM for up to 30 days.

Explosionsgefahr, wenn die Batterie falsch entfernt und/oder ersetzt wird. Entsorgen Sie benutzte Batterien in Übereinstimmung mit Ihren lokalen Umweltschutzbestimmungen.

If the FibreBridge becomes disconnected from power, recharging begins automatically when power is restored to the system. The battery is fully charged after 24 hours of continuous power application.

Fibre Channel port

The dual independent 4-Gigabit Fibre Channel ports can connect the FibreBridge to either a Fabric or Arbitrated Loop using a Small Formfactor Pluggable (SFP) interface. The FibreBridge 2400R/D auto negotiates with 1-Gb, 2-Gb and 4-Gb/sec. devices

SCSI ports

The two SCSI ports connect storage devices into the Fibre Channel Storage Area Network (SAN). Each port is totally independent from the other.

The ports are Ultra320 SCSI busses with VHDCI connector, downward compatible with all forms of single-ended SCSI and all previous SCSI protocols.

Management ports

The 10/100 Base T Ethernet port is accessible from the RJ45 connector to support local and remote diagnostics, monitoring and management.

The RS-232 serial port provides

 

 

support for remote monitoring

 

 

and management using a DB9

1

6

connector. The baud rate is

RX 2

7

programmable and preset at the

TX 3

8

4

9

factory to 115200 bps.

GND 5

 

9

ATTO Technology Inc. FibreBridge Installation and Operation Manual

Page 14
Image 14
ATTO Technology 2400C/R/D ATTO FibreBridge 2400R/D, Dimensions, Cooling and airflow, Power, Fibre Channel port, SCSI ports