Image 11
Manual reset switch

Manual reset switch

A manual reset switch reboots the FibreBridge.

To reset the FibreBridge, depress the reset button for no more than three seconds.

To restore factory defaults, press the reset button for more than four seconds until the green Ready LED blinks.

LED indicators

The LED indicators can be viewed from the connector (back) side and the front side of the FibreBridge 2390R/D. (See Exhibit 1.2-1)

LEDs on the connector (back) side are:

A bicolor Ready/Fault LED lights green to indicate ready, lights yellow to show a faulted condition, and is off to indicate not ready.

Embedded in the Ethernet port connector: a lighted green LED shows a valid link; off indicates

that no link is present. A separate blinking yellow LED indicates activity.

Fibre Channel port: A lighted green LED indicates link; off means no link. A separate green LED indicates activity if it is lit, no activity if it is off. SCSI ports: A green LED on each port indicates activity if is lit.

LEDs on the front panel are:

A bicolor Ready/Fault LED is lighted green to indicate ready, lighted yellow to show a faulted condition, and off indicates not ready.

SCSI ports: A green LED on each port indicates activity if is lit.

Fibre Channel port: bicolor LED indicates FC speed. If it is off, speed is 1-Gb; if it is green, 2-Gb, and yellow indicates 4-Gb FC. A separate green LED indicates activity if it is lit, no activity if it is off.

Exhibit 1.2-1 Fibre Bridge 2390R/D dimensions with front panel LEDs and connector side details

Ready, Fault LEDs

FC Activity, Link LEDs

SCSI Activity LEDs

Serial port Ethernet port Fibre Channel port SCSI ports