Command

Default

Example

 

 

 

SCSIDomainValidation

 

scsidomainvalidation

 

 

 

SCSIInitId

0x07

set scsiinitid 2 12

 

 

 

SCSIPortBusSpeed

ultra320

set scsiportbusspeed 2 ultra160

 

 

 

SCSIPortList

 

scsiportlist

 

 

 

SCSIPortReset

 

scsiportreset 1

 

 

 

SCSIPortResetOnStartup

enabled

set scsiportresetonstartup 1 disabled

 

 

 

SCSIPortSyncTransfer

enabled

set scsiportsynctransfer 2 disabled

 

 

 

SCSIPortTermination

enabled

set scsiporttermination 1 disabled

 

 

 

SCSIPortWideTransfer

enabled

set scsiportwidetransfer 2 disabled

 

 

 

SCSITargetLUNs

8

set scsitargetluns 1 64

 

 

 

SCSITargets

 

scsitargets 1

 

 

 

SerialNumber

 

get serialnumber

 

 

 

SerialPortBaudRate

115200

set serialportbaudrate 19200

 

 

 

SerialPortEcho

enabled

get seriallportecho

 

 

 

SNMP

enabled

set SNMP disabled

 

 

 

SNMPDumpMIB

 

snmpdumpmib

 

 

 

SNMPExtendedTraps

disabled

get snmpextendedtraps

 

 

 

SNMPTrapAddress

0.0.0.0 none

set snmptrapaddress 6 192.42.155.155 all

 

 

 

SNMPTraps

disabled

set snmptraps enabled

 

 

 

SNTP

enabled

get sntp

 

 

 

SNTPServer

192.43.244.18

set sntpserver 129.6.15.28

 

 

 

SpeedWrite

all disabled

get speedwrite scsi all

 

 

 

SpeedWriteDefault

disabled

set speedwritedefault enabled

 

 

 

TailEventLog

 

taileventlog

 

 

 

Temperature (FB2390, FB2400 only)

 

get temperature

 

 

 

Time

00:00:00

set time 03:32:30

 

 

 

TimeZone

EST

set timezone pst

 

 

 

TraceLog

disabled

set tracelog enabled

 

 

 

TraceLogFilter

all all all

set tracelogfilter all all all

 

 

 

Username

root

set username Barbara

 

 

 

VerboseMode

enabled

set verbosemode disabled

 

 

 

VirtualDriveResponse

disabled

set virtualdriveresponse enabled

 

 

 

VirtualRobotResponse

disabled

set virtualrobotresponse enabled

 

 

 

Voltage (FB2390, FB2400}

 

get voltage

 

 

 

WrapEventLog

enabled

set wrapeventlog disabled

 

 

 

WrapTraceLog

enabled

set wraptracelog disabled

 

 

 

zModem

 

zmodem receive

 

 

 

v

ATTO Technology Inc. FibreBridge Installation and Operation Manual

Page 36
Image 36
ATTO Technology 2370E, 2390C/R/D, 2400C/R/D operation manual Snmp

2400C/R/D, 2390C/R/D, 2370E specifications

ATTO Technology is a well-recognized name in the field of high-performance data storage and networking. Among its range of products, the ATTO 2390C/R/D, 2400C/R/D, and 2370E stand out due to their innovative features and advanced technologies tailored for demanding data environments. These devices are specifically designed for applications including digital media, video editing, and data-intensive tasks where speed and reliability are paramount.

The ATTO 2390 Series incorporates advanced features aimed at maximizing performance. One of its key characteristics is the support for multi-channel connectivity, which allows users to connect multiple systems and devices simultaneously. This is particularly beneficial in high-bandwidth applications where multiple data streams are processed simultaneously. In addition, the 2390 models feature a robust cache management system that accelerates data transfer rates, significantly reducing latency and enhancing overall efficiency.

The ATTO 2400 Series further enhances data management capabilities by supporting the latest protocol standards. This ensures compatibility with a wide range of storage systems and infrastructures, providing users with flexibility in their IT setups. Moreover, the 2400 models are optimized for PCIe Gen 4 technology, which delivers impressive throughput rates that cater to the most demanding applications, including 4K and 8K video editing.

The ATTO 2370E takes a slightly different approach, focusing on compatibility and scalability. Designed for high-performance computing environments, it features versatile connection options, including both SAS and SATA interfaces. This not only ensures high data transfer rates but also makes the device adaptable to various storage architectures, whether for entry-level consumers or enterprise solutions.

All three series integrate ATTO's proprietary Advanced Data Streaming (ADS) technology, allowing for smoother workflow by managing data transfers and reducing the bottleneck in high-load scenarios. This capability is essential for content production environments where seamless data handling is crucial.

In conclusion, the ATTO Technology 2390C/R/D, 2400C/R/D, and 2370E are pivotal in enhancing data storage solutions in today's fast-paced digital landscape. Combining high performance, compatibility with modern protocols, and intelligent data management features, these products are designed to meet the needs of professionals in media, entertainment, and enterprise sectors alike. With ATTO's commitment to innovation, users can expect reliable and efficient services that drive their productivity and workflow.