Avalon Stoves 790 Insert Installation for qualified installers only, Insert with, Direct, Z . C

Models: 790 745

1 44
Download 44 pages 20.04 Kb
Page 22
Image 22
22Insert Installation (for qualified installers only)

22Insert Installation (for qualified installers only)

 

NOTE: This installation may be

 

 

Insert with

used with a masonry or zero

 

 

 

 

 

clearance fireplace. This

Direct

illustration depicts a zero

Connection

clearance insert, all requirements

in the section "Zero Clearance

(Z . C .

Fireplace Requirements" must be

fulfilled prior to installation.

Fireplace)

 

 

 

 

 

 

Stainless steel

 

 

 

 

 

 

 

chimney connector

 

 

 

 

 

 

 

 

must Extend 1' past

 

 

 

 

 

 

 

the block-off plate.

N O T E :

Combustible Mantle

 

Direct

 

 

 

connections

Surround Panels

 

require installation

Damper must

 

of an airtight

 

be removed

 

 

block-off plate or

See the section

 

damper adapter

"Insert Placement

Block-off plate or

(see "Block-off

Requirements" for

minimum clearances

damper adapter

Plate Installation"

and hearth required.

 

on page 20)

 

 

 

 

Z.C. (Metal) firebox

 

 

Optional

 

 

Telescoping Legs

Insert

with

NOTE: This installation may be

used with a masonry fireplace

Face

Seal

only. The requirements in the

section "Masonry Fireplace

Connection

Requirements" must be fulfilled

prior to installation.

N O T E :

Flue

Face seal

Liner

 

connections

 

require installation

Combustible Mantle

of the surround

 

panels and

Surround Panels with

insulation (see the

"Surround Panel

insulation (see "Surround

Panels" installation

Installation" on

instructions in the back of

page 42)

the manual)

 

 

See the section "Insert

 

Placement Requirements"

 

for minimum clearances

 

and hearth required.

No modification to the firebox of the z.c. fireplace is allowed.

NOTE: It is recommended your chimney have a minimum 28 and a maximum of 144 square inch cross- sectional area to use a face seal connection, otherwise your chimney maynot have sufficient draw for the fireplace insert to operate correctly.

Airtight Insulated

Clean-Out

Remove damper or wire it open

Travis Industries

93508133

4 020509

Page 22
Image 22
Avalon Stoves 790 Insert Installation for qualified installers only, Insert with, Direct, Connection, Z . C, Fireplace