Avalon Stoves 790 Stove Installation for qualified installers only, C o n n e c t i o n, N O T E

Models: 790 745

1 44
Download 44 pages 20.04 Kb
Page 16
Image 16
16 Stove Installation (for qualified installers only)

16 Stove Installation (for qualified installers only)

H e a r t h S t o v e D i r e c t

C o n n e c t i o n

N O T E :

Direct connections require installation of an airtight, non- combustible block-off plate or damper adapter

NOTE: The chimney must have a clay tile liner. If it does not, the installation must use a positive connection (full reline). The entire fireplace and chimney must be clean, undamaged, and meet all local building codes (UBC, etc.). Damage must be repaired prior to installation. The chimney must be 15' to 33' tall.

Max. 8”

Combustible Mantle

Min. 18"

Floor Protection

(See the section "Floor H e a r t h S t o v e D i r e c t Protection Requirements" for more details) Interior or Exterior Masonry ChimneyManual background

Clay

Liner

Stainless steel chimney connector must Extend 1' past the block-off plate or to the flue liner

Airtight

Insulated

Clean-Out

Remove damper or wire it open

Block-off plate or damper adapter

See the section "Stove Placement Requirements" for minimum clearances required.

Interior or Exterior Masonry Chimney

N O T E :

This type of installation requires a UBC approved masonry connector or a factory built (U.L. Listed) wall thimble.

NOTE: The chimney must have a

 

 

 

clay tile liner. If it does not, the

 

 

 

 

 

 

installation must use a positive

 

 

 

 

 

 

connection (full reline). The

 

 

 

entire fireplace and chimney must

 

 

 

 

 

 

be clean, undamaged, and meet

 

 

 

 

 

 

all local building codes (UBC,

 

Min. 18"

 

etc.). Damage must be repaired

 

 

 

clearance

 

prior to installation. The chimney

 

 

 

to ceiling

 

must be 15' to 33' tall.

 

 

 

 

 

See the section "Stove Placement Requirements" for minimum clearances required.

Chimney connector sections

See the section

"Floor Protection

Requirements"

Clay Liner

This type of installation requires a UBC approved masonry connector or a factory built (U.L. Listed) wall thimble.

Make sure the clean-out seals in place.

Travis Industries

93508133

4 020509

Page 16
Image 16
Avalon Stoves 790, 745 Stove Installation for qualified installers only, Interior or Exterior Masonry Chimney, N O T E