Stove Installation (for qualified installers only) | 13 |
Mobile Home Requirements
•Outside air must be installed - see "Outside Air Requirements" on page 11
•Chimney connector and chimney must be one of the following types:
• DURAVENT model DVL with DURATEC chimney | • GSW Double Wall Chimney Connector with Super Chimney |
• DURAVENT model DVL with | • SELKIRK METALBESTOS model DS connector with model SSII chimney |
• | • I.C.C. Excel |
• SECURITY model DL with SECURITY model ASHT or S2100 chimney | • Standard Masonry Chimney with any one of the above listed connectors |
• |
|
NOTE: Reduced clearance connectors may not connect to the flue collar – order an appliance adapter for the connector being used.
•Stove placement must maintain the following clearances to combustibles (drywall, furniture, etc.)
Minimum | Clearance | 7 4 5 Reduced | 7 9 0 | Reduced | |
(See | the | illustration below) | Clearance |
| Clearance |
|
|
| Connector |
| Connector |
A | Sidewall to stove | 11" |
| 11" | |
B | Backwall to stove | 13" |
| 8 1/2" | |
C | Cornerwall to stove | 7 1/2" |
| 7 1/2" | |
D | Connector to sidewall | 19 1/2" |
| 19 1/2" | |
E | Connector to backwall | 9"* |
| 8 3/4" | |
F | Connector to cornerwall | 11"* |
| 15" |
*These are minimum clearances, not installation dimensions. Connector position will vary depending upon brand. First establish the stove clearances, install the 45° connector to the stove, then determine the position of the connector.
Corner Installations
Straight Installations
d
e | f |
a
b
c
NOTE:
Measure clearances to the stove top.
•If using offsets, use the connector clearance listed to the right, not the connector manufacturer's clearance.
•The appliance must be secured to the floor (consult your building official). Secure the outside air boot to the floor and stove to insure the stove does not dislocate.
•Mobile home installations require a spark arrester at the chimney termination.
•The appliance must be grounded to the chassis of the mobile home (consult your building official).
WARNING: DO NOT INSTALL IN SLEEPING ROOM.
CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED.
Minimum Connector Clearance
(as outlined above)
Minimum Stove Clearance
(as outlined above)
Travis Industries | 93508133 | 4 020509 |