Avalon Stoves 745, 790 owner manual Chimney Termination Requirements, Outside Air Requirements

Models: 790 745

1 44
Download 44 pages 20.04 Kb
Page 11
Image 11
Chimney Termination Requirements

Stove Installation (for qualified installers only)

11

Chimney Termination Requirements

Must have an approved cap (to prevent water from entering)

Must not be located where it will become plugged by snow or other material

Must terminate at least 3' above the roofa n d at least 2' above any portion of the roof within 10'

Slanted Roofs

Chimney must extend 3' above the roof

Chimney must extend 2' above any portion of the roof within 10' of the chimney

Flat

Chimney must extend 3' above the roof

Chimney must extend 2' above any portion of the roof within 10' of the chimney

Outside Air Requirements

Required for mobile homes & in certain localities (check with building officials)

Must not be drawn from an enclosed space (garage, unventilated crawl space)

Requires the optional outside air boot (for legs) or pedestal.

When using outside air, find a location where the chimney and outside air hole do not interfere with structural members of the home.

Pedestal (with insulation)

directs air to the stove.

A hole must be cut through the floor protection and floor and the rodent screen nailed in place here (see the optional equipment instructions for exact sizes)

Outside

Air Boot

Air may be drawn from a ventilated crawl space or use an air duct.

Optional Air Duct (must not be longer than 15' and at least 16 square inches in cross section)

Outside air entrance must be placed so it does not become blocked by snow.

Travis Industries

93508133

4 020509