Avalon Stoves 745 Stove Installation for qualified installers only, C o n n e c t i o n, N O T E

Models: 790 745

1 44
Download 44 pages 20.04 Kb
Page 15
Image 15
E x t e r i o r

Stove Installation (for qualified installers only)

15

E x t e r i o r

F a c t o r y

B u i l t

C h i m n e y

N O T E :

Exterior chimneys are subject to greater moisture and creosote accumulation due to the lower temperatures. An insulated chase will reduce these accumulations (the proper clearances to the chimney must be maintained).

Chimney Cap

 

 

Follow the chimney

 

 

manufacturer's

(See the section "Chimney

 

 

 

}

instructions and

Termination Requirements"

clearances for roof

for more details)

 

 

penetrations. A storm

 

 

Chimney Sections

collar and flashing are

required (some

 

 

Minimum Air Space to

 

require a radiation

Combustibles (See

 

shield).

Chimney Manufacturer's

Wall Bands

Minimum 15'

Instructions - usually 2")

and

Maximum 33'

 

Supports

 

 

 

Min. 18"

 

Insulated Tee

clearance to

 

(with cleanout )

ceiling

}

Follow the chimney

 

 

manufacturer's

Chimney Connector

instructions and

 

 

 

 

clearances for wall

 

 

 

 

 

 

penetrations. A

 

 

 

wall radiation shield

Floor Protection

 

 

(thimble) is

(See "Floor

 

Stove Clearances

required.

Protection

 

 

 

(See the section "Stove

Optional

Requirements"

 

 

Placement Requirements"

insulated

for details)

 

 

for more details)

chase

 

 

H e a r t h S t o v e P o s i t i v e

C o n n e c t i o n

N O T E :

Most factory-built chimney manufacturers make stainless steel chimney liners, either flexible or rigid. This provides a wide variety of installation options. Make sure to follow the manufacturer's instructions for installation and support

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cap and flashing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

prevents water from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: The entire fireplace and

 

 

 

 

 

 

 

 

 

 

 

 

entering

 

 

 

 

chimney must be clean, undamaged,

 

 

 

 

 

 

 

 

 

 

 

 

 

and meet all local building codes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(UBC, etc.). Damage must be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

repaired prior to installation. The

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

chimney must be 15' to 33' tall.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The liner must be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stainless steel connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or flexible vent. Follow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the liner manufacturer's

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

instructions for installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustible

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and support.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mantle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. 18"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airtight Insulated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean-Out

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove damper

Floor Protection

or wire it open

 

(See the section

 

"Floor Protection

See the section

Requirements"

"Stove Placement

for more details)

Requirements" for

 

minimum clearances

 

required.

Travis Industries

93508133

4 020509

Page 15