Multiplexer Mode

How to Display

Note: This window can be displayed only when “Yes” is selected in the Recorder window. (Refer to p. 66.)

Parameters

To display this window, click on the (Multiplexer Mode) button in the main window (p. 65.)

• Multi Monitor Out Group

Still Display: Select the desired setting by clicking on the drop-down menu.

ON: Still picture is available during the multiscreen dis- play.

OFF: Still picture is not available during the multiscreen display.

The factory default setting is ON.

Border Color: Select the desired setting by clicking on the drop-down menu. This setting will determine the color of the border which separates each multi- screen segment.

WHITE: The border will be displayed in white.

GRAY: The border will be displayed in gray.

BLACK: The border will be displayed in black.

OFF: No border will be displayed.

The factory default setting is WHITE.

Quad Shift: Select the desired setting by clicking on the drop-down menu.

ON: Camera images are displayed in 4 multiscreen segments (quad) and switched as follows:

4A = Page 1 of the quad (Camera 1, 2, 3 and 4)

4B = Page 2 of the quad (Camera 5, 6, 7 and 8)

4C = Page 3 of the quad (Camera 9, 10, 11 and 12)

4D = Page 4 of the quad (Camera 13, 14, 15 and 16)

OFF: Quad is unavailable.

The factory default setting is OFF.

Secret View: Select the desired setting by clicking on the drop-down menu.

ON: The drop-down menu becomes also active so that you can select the desired monitor among MON 1 to 4. For example, when you select MON 1, other operators, whose priority is lower than you, cannot view the monitor (secret view).

OFF: Secret view function is unavailable.

The factory default setting is OFF.

Sequence Mode: Select the sequence type by clicking on the radio button.

Quad: Multiplexer sequence is activated. The monitor display will be changed as 4A 4B 4C 4D.

3+1: Images are displayed in 4 multiscreens, and the images of Camera 4 to 16 are displayed in the sequence mode, at the right bottom of the monitor. The images of Camera 1 to 3 are fixed. (Refer to the left-side illustration in p. 19.)

8+1: Images are displayed in 9 multiscreens, and the images of Camera 9 to 16 are displayed in the sequence mode, at the right bottom of the monitor. The images of Camera 1 to 8 are fixed. (Refer to the right-side illustration in p. 19.)

The factory default setting is Quad.

Dwell: The dwell time of the selected sequence mode is selectable. 2S to 30S is available.

The factory default setting is 2S.

• REC OUT Group

Title Display: Select the desired setting by clicking on the drop-down menu.

ON: The camera title is displayed on the recorded image.

OFF: The camera title is not displayed on the recorded image.

The factory default setting is ON.

Clock Display: Select the desired setting by clicking on the drop-down menu.

ON: The date and time are displayed on the recorded image.

OFF: The date and time are not displayed on the recorded image.

The factory default setting is ON.

Normal Group

REC Mode: Select the desired setting by clicking on the radio button.

EXT: Select this to gen-lock the unit during the normal recording.

INT: Select this if the asynchronous unit is connected to the unit. When it is activated, the drop-down menu becomes also active so that you can select the desired normal recording rate. 002, 004 to 255 (field) are selectable.

The factory default setting is EXT.

82

Page 80
Image 80
Panasonic WJ-SX 150 Multiplexer Mode, How to Display Parameters, Multi Monitor Out Group, REC OUT Group, Normal Group