24
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS

WJ-SX150 Matrix Switcher

Front View
qOperation indicator (OPERATE)
Lights up when the power of the unit is turned on.
Note: The indicator will blink to indicate rising tempera-
ture in the matrix switcher.
When the indicator blinks, turn the power off and
refer servicing to qualified service personnel.
wReset button (RESET)
Resets and restarts the unit.
Note: The system configuration is not reset.
eUnit number selector (UNIT)
This selector is reserved for future use.
Normally, set this switch to "1".
rMode selector (MODE)
Selects the unit's operation mode.
Normally, set all switches to OFF (NORMAL mode) as
shown in the figure.
SX150 SOFTWARE UPLOAD:
Set the switches to this position when you update
the firmware of the unit. (Refer to the operating
instructions of the multiplexer board.)
MULTIPLEXER SOFTWARE UPLOAD:
This mode is reserved for future use.
Matrix Switcher WJ-SX
OPERATE
OPERATE LED WILL BLINK
IF COOLING FAN MALFUNCTIONS
q
0
9
8
7
6
5
4
3
2
1
MODEUNITRESET
we r
1
ON
234
1
ON
234
1
ON
234
1
ON
234
NORMAL
SX150
SOFTWARE UPLOAD
MULTIPLEXER
SOFTWARE UPLOAD

MODE SW SETUP