Alarm Control

Item

Transmission Command

Response (ASCII)

Parameter (ASCII)

(ASCII)

 

 

 

 

 

 

 

Alarm input

OAIcc

No response

cc=Alarm No.

 

 

 

 

Alarm ACK

CMD:HmmAK

ANS:HmmAK

mm=Monitor No.

(Each monitor)

 

 

 

 

 

 

 

 

Alarm reset

CMD:HmmAR

ANS:HmmAR

mm=Monitor No.

(Each monitor)

 

 

 

 

 

 

 

 

Alarm all reset

CMD:H00AR

ANS:H00AR

 

 

 

 

 

Alarm suspension

MAD

MADn

Transmission command toggles alarm sus-

 

 

 

pension ON or OFF.

 

 

 

n=0 OFF

 

 

 

n=1 ON

 

 

 

 

Setup Control

Item

Transmission Command

Response (ASCII)

Parameter (ASCII)

(ASCII)

 

 

 

 

 

 

 

Display SETUP MENU

CMD:HmmSS

ANS:HmmSS

mm=Monitor No.

 

 

 

 

Return to normal view*

CMD:HmmSE

ANS:HmmSE

mm=Monitor No.

*Available only in SETUP MENU

 

 

 

 

 

 

 

Move the cursor leftward

CMD:AmmJL

mm=Monitor No.

 

 

 

 

Move the cursor rightward

CMD:AmmJR

mm=Monitor No.

 

 

 

 

Move the cursor upward

CMD:AmmJU

mm=Monitor No.

 

 

 

 

Move the cursor downward

CMD:AmmJD

mm=Monitor No.

 

 

 

 

Enter "0"

CMD:AmmT0

mm=Monitor No.

 

 

 

 

Enter "1"

CMD:AmmT1

mm=Monitor No.

 

 

 

 

Enter "2"

CMD:AmmT2

mm=Monitor No.

 

 

 

 

Enter "3"

CMD:AmmT3

mm=Monitor No.

 

 

 

 

Enter "4"

CMD:AmmT4

mm=Monitor No.

 

 

 

 

Enter "5"

CMD:AmmT5

mm=Monitor No.

 

 

 

 

Enter "6"

CMD:AmmT6

mm=Monitor No.

 

 

 

 

Enter "7"

CMD:AmmT7

mm=Monitor No.

 

 

 

 

Enter "8"

CMD:AmmT8

mm=Monitor No.

 

 

 

 

Enter "9"

CMD:AmmT9

mm=Monitor No.

 

 

 

 

SET

CMD:AmmST

mm=Monitor No.

 

 

 

 

ESC

CMD:AmmES

mm=Monitor No.

 

 

 

 

INC

CMD:AmmIN

mm=Monitor No.

 

 

 

 

DEC

CMD:AmmDE

mm=Monitor No.

 

 

 

 

NEXT

CMD:AmmNX

mm=Monitor No.

 

 

 

Available in SETUP MENU, Alarm History

 

 

 

and Video Loss History

 

 

 

 

PRE

CMD:AmmPR

mm=Monitor No.

 

 

 

Available in SETUP MENU, Alarm History

 

 

 

and Video Loss History