■ Alarm Mode
This window configures the operation parameters when an alarm signal is input: an alarm mode, auto reset time and alarm input.
(Save Exit) button:
Saves the configuration and closes the Daylight Saving
Time window.
(Cancel Exit) button:
Cancels the configuration and closes the Daylight Saving
Time window.
● How to Display
To display this window, click on the (Alarm Mode) but- ton in the main window (p. 65).
● Parameters
• Alarm Mode
Checking on the box of the desired alarm mode.
OFF: The system operation does not change into any other mode.
Sequence Mode: Camera images are displayed on the monitor in either the spot mode or tour sequence. When more than one alarm are input, the image associated to each alarm is displayed in the sequence mode.
Note: Click on the Dwell
Hold Mode: Camera images are displayed on the mon- itor in either the spot mode or tour sequence. Even more than one alarm are input, the image associat- ed to the initial alarm is continuously displayed.
Notes:
• The alarm mode is activated when alarm input signals are assigned to the same monitor through 420 ALARM EVENT or the Alarm Event (refer to p. 56 or p. 74) win- dow.
• While alarm is activated, you cannot operate the func- tions related to the multiplexer board.
• Alarm Input Group
Select the alarm input to be accepted. Multiple Selection is available.
Camera
72
This stands for that an alarm input is accepted via the CAMERA IN connectors or the
ON: The