80
2.048Mb
p
s Wireless Modem
SALES: 0118 965 5100
Message: WARNING: Delay setting may be too short to correct
all errors
Description: The selected delay setting might be too short to allow the ARQ to correct the
bursts of radio errors present. Correction: Increase the delay setting or identify
and eliminate the cause of the bursts by using the tracers.
General Alarms
Message: WARNING: LIU Clock drift, Check clock configuration
Description: In E1/T1 configuration, failure to set the clock source of the end equipment
connected to the slave unit to loop-back mode.
Correction: Check the clock configuration.
Message: WARNING: LIU Clock frequency differs from set value
Description: Indicates a clock rate different from the one specified in a V.35/RS-530/X.21
unit configured as DCE EXTERNAL CLOCK or as DTE.
Correction: Correct clock frequency to set value.
Message: WARNING: DPLL is noisy due to bad link conditions or
noisy input clock
Description: Indicates that bad link conditions prevent the slave unit from synthesizing a
stable LIU clock.
Correction: Check the link and the clock.
Message: WARNING: Too many links to synchronize, Reduce
requested number
Description: The specified number of links to s ynchronize is too high for the selected
hopping standard.
Correction: Reduce the number of links to synchronize.