2.048Mbps Wireless Modem
•Copy local database and download to remote unit.
Table 3-12. REMOTE Parameters Menu Options
Switch to Remote Monitor
When selecting option 1 (Switch to remote monitor) in the REMOTE Parameters Menu, the database of the remote unit starts loading into the local unit. This process takes some time, and the time required is even longer if the quality of the link is poor. Once the remote database is loaded, you can view or change the parameters of the remote unit. At this state, an indication of being in “Remote Monitor” mode appears at the end of the first line of each menu.
Switch to Local Monitor
When selecting 2 in the REMOTE Parameters Menu, the “Switch to local monitor” menu appears:
0 – Switch back to local monitor (remote database will be lost) 1 – Do not switch back to local monitor.
Note: If parameters of the remote units were changed, select 4 in the REMOTE Parameters Menu (Download remote database to remote unit) before switching back to local monitor mode. Note that this takes effect only after resetting the unit.