67
2.048Mb
p
s Wireless Modem
TECHNICAL: 0118 931 2233
Ping Remote Unit
The remote management process involves transfer of large quantities of data between the
units, in addition to normal data and signals. Since this transfer can take a long time, the
PING mode is used to verify that there is a working link between the two units and that
remote management operation is feasible. Entering this mode causes transmission of a short
“PING remote” message, followed shortly by a “PONG received” message indicating the
existence of a remote management link.
Download remote database to remote unit
When selecting 4 in the REMOTE Parameters Menu, the Download remote database
selection menu appears:
0 – Download database. All changes will take effect.
1 – Do not download database yet.
Reset the remote unit for the changes to take effect.
Copy database and download to remote unit
Typically, this is the simplest, fastest and safest procedure for changing parameters in the
remote unit, assuming that parameters of the local and remote units are the same. The remote
unit will automatically adapt its Master/Slave parameter (if the parameter in the database is
Master, the remote unit will change its setting to Slave and vice versa). When selecting 5 in
the REMOTE Parameters Menu, the Copy local database and download to remote unit
selection menu appears:
0 – Copy database and download to remote unit. All changes will take effect.
1 – Do not copy database and download to remote unit yet.
Reset the remote unit for the changes to take effect.
Load Default Values Menu
The Load Default Values menu gives you access to the following options:
Cancel Operation
Load Values