2.048Mbps Wireless Modem

Ping Remote Unit

The remote management process involves transfer of large quantities of data between the units, in addition to normal data and signals. Since this transfer can take a long time, the PING mode is used to verify that there is a working link between the two units and that remote management operation is feasible. Entering this mode causes transmission of a short “PING remote” message, followed shortly by a “PONG received” message indicating the existence of a remote management link.

Download remote database to remote unit

When selecting 4 in the REMOTE Parameters Menu, the Download remote database selection menu appears:

0 – Download database. All changes will take effect.

1 – Do not download database yet.

Reset the remote unit for the changes to take effect.

Copy database and download to remote unit

Typically, this is the simplest, fastest and safest procedure for changing parameters in the remote unit, assuming that parameters of the local and remote units are the same. The remote unit will automatically adapt its Master/Slave parameter (if the parameter in the database is Master, the remote unit will change its setting to Slave and vice versa). When selecting 5 in the REMOTE Parameters Menu, the Copy local database and download to remote unit selection menu appears:

0 – Copy database and download to remote unit. All changes will take effect. 1 – Do not copy database and download to remote unit yet.

Reset the remote unit for the changes to take effect.

Load Default Values Menu

The Load Default Values menu gives you access to the following options:

Cancel Operation

Load Values

TECHNICAL: 0118 931 2233

67

Page 67
Image 67
Black Box MWU2000-X21, MWU2000-G703 Load Default Values Menu, Ping Remote Unit, Download remote database to remote unit