Black Box MWU2000-G703, MWU2000-X21 Message Warning Difference in parameters between two units

Models: MWU2000-G703 MWU2000-X21 MWU2000-V35

1 132
Download 132 pages 12 Kb
Page 81
Image 81

2.048Mbps Wireless Modem

Message: WARNING: Net I.D. too high (relevant only regarding synchronization)

Description: The Net I.D. for a link that should be synchronized is higher that the requested number of links to synchronize.

Correction: Adjust the Net I.D.

Message: WARNING: Difference in parameter(s) between two units

Description: Different setting of parameters in the two units forming the links. This message will be followed by more details, as follows:

Normal/Test Mode Setting: one of the units is in Test mode and the other one is set to Normal mode.

HOP Standard Setting: different HOP standards setting are used in the two units.

HOP Sequence setting: different hopping sequences are selected in the two units.

Test Sequence channels: different sequences used in test mode

Clock Rate: different clock rates selected in the two units.

Delay Setting: different link delay settings in the two units.

Master/Slave setting: both units are defined as Master.

Echo Canceler parameters: in a fractional E1/T1 application, different echo canceler parameters (disabling method) are selected in the two units.

E1/T1 Channel Selection: in a fractional E1/T1 application, different channels are selected in the two units.

Echo Canceler Channels: in a fractional E1/T1 application, a difference in the channels in which echo cancellation is used in the two units.

E1/T1 Parameters setting: different parameters used in the two units in a E1/T1 application.

Correction: Configure the parameters properly.

Note: HOP Standard setting can only be configured by an authorized Black Box technician.

TECHNICAL: 0118 931 2233