SETUP PROCEDURES
■Setup Procedures
This unit has two setting procedures.
The one is SETUP MENU, which is the unit's
The other is
| Sequence settings |
|
| • Tour sequence |
|
| • Group sequence |
|
| Schedule settings |
|
| • Timer event |
|
| • Camera cleaning |
|
| • Daylight saving time |
|
(PC) | Alarm settings |
|
• Alarm mode |
| |
AdministratorConsole | • Alarm event | SETUPMENU(OSD) |
• Cable compensation | ||
| • Alarm input/Alarm port |
|
| Operator settings |
|
| • Operator registration |
|
| • Level table |
|
| • Monitor select (Monitor selection) |
|
| • Auto login/logout (Auto |
|
| System settings |
|
| • Clock (Time and date) *1 |
|
• Camera title |
| |
• Data port *2 |
| |
Multiplxer board |
| |
WJ |
|
|
• Recorder |
| |
• Multiplexer *3 |
| |
| • Mux (Multiplxer camera title) *3 |
|
Setup file operation
•Put a file to SX150
•Get a configuration data from the SX150
SX150 Admin Console Configuration
•File Open
•Account Manager
•Communication (Serial) port
• Camera manual cleaning ON/OFF
*1
*2
*3 These menus (or windows) appear only when the Multiplxer is installed in the unit.
• SETUP MENU (OSD)
The basic functions, which are essential for the operation, are configurable. However, some items are not config- urable. The settings about group sequences, operators and schedules, etc.
• WJ-SX150 Administrator Console (PC)
All the functions of this unit are configurable. You need a PC to use
Refer to p. 64
Notes:
•To use
•When changing the configuration of
■Description of Setup Procedures
This chapter describes about configurable items.
●Sequence Settings
SETUP MENU can configure tour sequences.
•Tour sequence: Up to 16 tour sequences are config- urable (16 steps per tour).
•Group sequence: Tour sequences can be activated on up to 4 monitors simultaneously (1 tour sequence per monitor).
●Schedule Settings
SETUP MENU can configure daylight saving time. WJ- SX150 Administrator Console can configure timer event, camera cleaning, and daylight saving time.
•Timer event: A sequence or spot mode can be activat- ed on the regular time of every month, week or day.
Up to 30 timer events can be registered.
•Camera cleaning: Camera cleaning can be executed on the regular time of every month, week or day.
•Daylight saving time: Daylight saving times for 20 years are configurable.
●Alarm Settings
The operation parameters when an alarm is input to the unit are configurable.
•Alarm mode: The operation mode activated along with an alarm input is configurable. Sequence mode or hold mode is selectable. Alarm mode can be set to OFF when not using it.
•Alarm event: The event activated along with an alarm input is assignable to each alarm input terminals. The sequence number or spot camera is selectable for the alarm event.
•Alarm input (Alarm port): The alarm polarity (N. O. or N. C.) is assignable to each alarm input terminal. One of 16 terminals is assignable for time adjustment.
50