CAM: This stands for the camera number.
COMP: This stands for cable compensation.
Select the desired setting according to the cable length.
S:Less than 400 m (1 300 ft)
M:400 m (1 300 ft) to 700 m (2 300 ft)
L:700 m (2 300 ft) to 900 m (3 000 ft)
Refer to p. 37 for available cables.
The factory default setting is S.
VD2: To send the VD2 timing pulse with the camera output signal, select ON. Not to send the VD2 tim- ing pulse with the camera output signal, select OFF. The factory default setting is ON.
DATA: To send the control data with the camera output signal, select ON. Not to send the control data with the camera output signal, select OFF. The factory default setting is ON.
After the configuration, press the MON (ESC) button. The monitor display returns to the previous menu.
• RS485 CAMERA SETUP
This menu links to the submenu.
Move the cursor and press the CAM (SET) button to go into the menu. 720 RS485 CAMERA will appear on the monitor.
720 RS485 CAMERA |
|
| ||
CAM | PORT | CAM | PORT | |
1 |
| 9 | ||
2 |
| 10 | ||
3 |
| 11 | ||
4 |
| 12 | ||
5 |
| 13 | ||
6 |
| 14 | ||
7 |
| 15 | ||
8 |
| 16 |
CAM: This stands for the camera number.
PORT: This stands for the data port to which an
•
•RS485: Select this when connecting the camera to an
•DATA1: Select this when connecting the camera to the DATA 1 port.
•DATA 2: Select this when connecting the camera to the DATA 2 port.
•DATA 3: Select this when connecting the camera to the DATA 3 port.
The factory default setting is DISABLE (for CAM 1 to 16).
Note: The settings of camera inputs without camera con- nections are ignored.
• DATA4/PSD PORT SELECT
This stands for the operation mode: PS·Data or the terminal mode.
PSD: Select this when connecting a PS·Data controller to the DATA 4 port.
DATA 4: Select this when connecting a
The factory default setting is PSD.
• PSD/HDR PORT SPEED
This stands for the PS·Data communication speed (or baud rate) of the DATA 4 port.
19200, 9600 or 4800 bps is selectable.
The factory default setting is 9600 bps.
• SERIAL PORT SPEED
Select the desired communication speed for SERIAL (the serial port), with the NEXT or PREV button.
38400 bps: The speed is set to 38400 bps.
19200 bps: The speed is set to 19200 bps.
9600 bps: The speed is set to 9600 bps.
4800 bps: The speed is set to 4800 bps.
The factory default setting is 38400 bps.
After the configuration, press the MON (ESC) button. The monitor display will return to the previous menu.
After all the configurations, press the SETUP button while holding down the SHIFT button. The configuration will be updated when closing SETUP MENU.
• EXT IN
This stands for the setting of the EXT IN connector at the unit's rear panel.
This menu does not appear when the Multiplexer board is installed in the unit.
GENLOCK
ON: Select this mode to
OFF: Select this mode if the asynchronous unit is con- nected with the recorder.
The factory default setting is GENLOCK OFF.
Notes:
•If GENLOCK ON is selected, the playback images or multiscreen display cannot be displayed on Monitor 1 to 4. Confirm the images on the monitor which are con- nected to the recorder.
•If GENLOCK OFF is selected, the maximum rate recording becomes unavailable (when