■Data Port
This window configures the parameters of each data port (RS485, DATA 1 to 4 and DATA HDR port): the protocol, the baud rate (communication speed), and the connected cameras.
●How to Display
To display this window, click on the (Data Port) button in the main window (p. 65).
●Parameters
• RS-485 Port Group
Protocol: Select RS485 when an
Select CU360C when the system controller is con- nected to the data port.
Select PSD when the system controller is connected to the DATA 4 port via the PS·Data protocol. PS·Data mode will appear in the window.
Note: The baud rate of DATA HDR is the same as that of PSD. When you select PSD for DATA 4, DATA HDR and its baud rate are displayed in gray and not configurable. When you select CU360C for DATA 4, DATA HDR and its baud rate are configurable.
Baud Rate: Select the desired baud rate (communica- tion speed). 4800, 9600 or 19200 bps is selectable.
RS485 Camera Daisy
Data 1 to 3 are connectable to either of cameras and system controllers.
When connecting cameras to these ports, select the connected camera number(s).
PS·Data mode: This stands for the PS·Data parameters of the DATA 4 port.
Logout Time: Select the desired operable time before logout. OFF,10, 20, 30, 60, 90 or 120 sec is available.
The factory default setting is 30 sec.
Alarm Data: Select the desired time to accept an alarm input signal. OFF, 0, 1 or 5 sec is avail- able.
The factory default setting is 1 sec.
Wait Time: Select the desired wait time to transmit an alarm output signal. OFF, 100msec, 200m sec, 400m sec or 1 sec is available.
The factory default setting is OFF.
Group Address: This parameter is only for confir- mation. Leave as it is.
• Fixed Common Parameter Group
The data bit (8 bit), parity (none), and stop bit (1 bit) are displayed. These parameters are fixed.
(Save Exit) button
Saves the configuration and closes the Data Port window.
(Cancel Exit) button
Cancels the configuration and closes the Data Port window.