I/O Setup and System Configuration

PARAMETER

configuration: retransmission 0%

configuration: retransmission 100%

configuration: CAT control setpoint value

configuration: alarm setpoint value

configuration: configuration: On/Off control cycle timer setpoint value

configuration: PFT control setpoint value

configuration: DAT control setpoint value

configuration: CAT control proportional band limit

configuration: alarm deadband

configuration: On/Off control cycle timer deadband

configuration: PFT control proportional band limit

configuration: DAT control proportional band limit

configuration: alarm delay

configuration: process variable or computed value to be used as basis for discrete control output

configuration: process variable or computed value alarmed

configuration: alarm action

configuration: On/Off control cycle timer period

configuration: On/Off control cycle timer “on” time

configuration: PFT control maximum pulse frequency

configuration: DAT control cycle period

configuration: 24-hour clock set mode

configuration: 24-hour clock set hour

configuration: 24-hour clock set minute

configuration: AutoClean timer set day

configuration: AutoClean timer set hour

configuration: AutoClean timer set minutes

CHOICES or RANGE (Default is underlined)

range depends on measurement type and cell constant; default is value of lower range limit

range depends on measurement type and cell constant; default is value of upper range limit

range depends on measurement type and cell constant; default is value of upper range limit

0 to 100 seconds, default = 0

C1 [Cell 1 value]

C2 [Cell 2 value]

TMP1 [temperature value from Cell 1] TMP2 [temperature value from Cell 2]

T1/2 [temperature 1 and/or 2 - only available for alarming]

Cell1

RATO [computed ratio: Cell2 ]

 

(1

Cell1

)x100

 

 

 

%REJ [computed percent rejection:

 

 

Cell2

]

 

 

Cell1

x100

 

%PSG [computed percent passage: Cell2

]

DIFF [computed difference: Cell1 Cell2 ]

CO2 [computed parts per million carbon dioxide - 9782C-S0 only]

HIGH

LOW

0 to 1000 seconds, default = 60

0 to 100% at 1% resolution, default = 100

1 to 200 pulses per minute, default = 60

0 to 200 seconds, default = 60

OFF

ON W/ RESET

ON W/O RESET

0 to 24, default = 1

0 to 59, default = 0

0 to 28, default = 0

0 to 24, default = 1

0 to 59, default = 0

7/99

9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual

5-25

Page 81
Image 81
Honeywell 9782 Series manual Configuration alarm deadband