Unpacking, Preparation, and Mounting

Vertical Rear Pipe Mounting

7.64 ±.070

194.06 ±1.78

inches

LEGEND: millimeters

1.00 IPS Pipe

25.40 (by customer)

3.06

77.80

7.68±.060

195.07 ±1.52

Note 1: Do not exceed 80 lb-in torque when tightening fastners.

Top View

7.64 ±.070

194.06 ±1.781.50

38.10

Panel Mounting

into existing 7075, 7076, 7077, and 7078 series cutouts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

3.00

 

 

 

L

 

76.20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Four holes in bracket or 1/4 dia. mounting bolts (bolts by customer)

1.27±.025 32.26 ±0.64

.25 max.

6.35 Customer Panel

C

L6.43 ±0.70 163.32 ±1.78

6.27 ±.040

159.26 ±1.02

R.H. Side View

Wall Mounting

C

L

7.68±.060

195.07 ±1.52

Panel Mounting

6.63

168.40

3.31

84.07

1.21 ±.025

30.73 ±0.64

.12 min. .37 max.

3.04 9.40 Customer Panel

C

L6.43 ±0.70 163.32 ±1.78

6.27 ±.040

159.26 ±1.02

Figure 3-3-2 Mounting and Dimensions – Backlit Display Option

7/99

9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual