Problem

Check item

Remedy

The camera image is dim.

Dust may be sticking on the camera lens.

Remove the dust from the camera lens.

The camera’s lens focus may not be proper.

Press the FOCUS NEAR/ FAR buttons to adjust the lens focus. If the camera supports auto focus, press these but- tons simultaneously. The lens focus can be adjusted automatically.

The camera’s cable compensation set- ting may not be proper.

Open 710 COMPENSATION/VD2/DATA (refer to p. 60) or the Cable Compensa- tion/VD2 window (refer to p. 78) to con- firm the setting.

The camera is not operable.

The camera may not have been select-

Select the camera again. (Refer to p.

ed.

91.)

 

 

The camera may not support the func-

Confirm whether the camera supports

tion you try to execute.

the function. (Refer to the camera's

 

operating instructions.)

 

 

The camera's cable setting may wrong.

Open 710 COMPENSATION/VD2/DATA

 

(refer to p. 60) or the Cable

 

Compensation/VD2/DATA (refer to p.

 

78) window to confirm the setting. If the

 

camera’s DATA is set to OFF, the RS-

 

485 cameras will not be operable.

 

 

The data port setting may wrong.

Open the Data Port window (refer to p.

 

81) and confirm the setting.

When the BUSY indicator is lighting on the system controller, a higher-priority operator has selected the camera.

Select another camera.

Wait until a higher-priority operator fin- ishes controlling the camera.

While the PROHIBITED indicator is lighting on the system controller, you are prohibited to control the camera.

Open the Operator Registration window (refer to p. 75) and reconfigure the set- ting.

OSD items (Clock, Camera title, Monitor status, Event) overlap one another.

Turn off an overlapping item. (Refer to p. 99.)

Move OSD items. (Refer to p. 99.)

Change the area title display position through the camera’s setup menu. (Refer to the camera’s operating instructions.)

Tour/group sequence is not activated.

The tour/group sequence setting may

Open 300 SEQUENCE (refer to p. 55),

be wrong.

the Tour Sequence (refer to p. 68) or

 

Group Sequence (p. 69) window and

 

reconfigure the setting.

 

 

The setting has not been put from the

Put the configuration data to the unit

PC to the unit.

again after the configuration. (Refer to

 

p. 67 Put a File to SX150.)

 

 

When the PROHIBITED indicator is

Open 800 OPERATOR REGISTRATION

lighting on the system controller, you

(refer to p. 62) or the Operator

are prohibited to control the camera.

Registration window (refer to p. 75) and

 

reconfigure the setting.

129

Page 125
Image 125
Panasonic WJ-SX 150 manual 129