Problem | Check item | Remedy |
The camera image is dim.
Dust may be sticking on the camera lens.
Remove the dust from the camera lens.
The camera’s lens focus may not be proper.
Press the FOCUS NEAR/ FAR buttons to adjust the lens focus. If the camera supports auto focus, press these but- tons simultaneously. The lens focus can be adjusted automatically.
The camera’s cable compensation set- ting may not be proper.
Open 710 COMPENSATION/VD2/DATA (refer to p. 60) or the Cable Compensa- tion/VD2 window (refer to p. 78) to con- firm the setting.
The camera is not operable.
The camera may not have been select- | Select the camera again. (Refer to p. |
ed. | 91.) |
|
|
The camera may not support the func- | Confirm whether the camera supports |
tion you try to execute. | the function. (Refer to the camera's |
| operating instructions.) |
|
|
The camera's cable setting may wrong. | Open 710 COMPENSATION/VD2/DATA |
| (refer to p. 60) or the Cable |
| Compensation/VD2/DATA (refer to p. |
| 78) window to confirm the setting. If the |
| camera’s DATA is set to OFF, the RS- |
| 485 cameras will not be operable. |
|
|
The data port setting may wrong. | Open the Data Port window (refer to p. |
| 81) and confirm the setting. |
When the BUSY indicator is lighting on the system controller, a
•Select another camera.
•Wait until a
While the PROHIBITED indicator is lighting on the system controller, you are prohibited to control the camera.
Open the Operator Registration window (refer to p. 75) and reconfigure the set- ting.
OSD items (Clock, Camera title, Monitor status, Event) overlap one another.
•Turn off an overlapping item. (Refer to p. 99.)
•Move OSD items. (Refer to p. 99.)
•Change the area title display position through the camera’s setup menu. (Refer to the camera’s operating instructions.)
Tour/group sequence is not activated.
The tour/group sequence setting may | Open 300 SEQUENCE (refer to p. 55), |
be wrong. | the Tour Sequence (refer to p. 68) or |
| Group Sequence (p. 69) window and |
| reconfigure the setting. |
|
|
The setting has not been put from the | Put the configuration data to the unit |
PC to the unit. | again after the configuration. (Refer to |
| p. 67 Put a File to SX150.) |
|
|
When the PROHIBITED indicator is | Open 800 OPERATOR REGISTRATION |
lighting on the system controller, you | (refer to p. 62) or the Operator |
are prohibited to control the camera. | Registration window (refer to p. 75) and |
| reconfigure the setting. |