●Moving the Event Display
Move the joystick while holding down the OSD, SHIFT and 3 buttons. (3) will move to the desired direction.
●Moving the Monitor Status*
Move the joystick while holding down the OSD, SHIFT and 4 buttons. (4) will move to the desired direction.
* Monitor number, controller number and monitor mode
●Moving All the Items
Move the joystick while holding down the OSD, SHIFT and 5 buttons. (1), (2), (3), and (4) will move to the desired direction.
■System Status Table
The table shows the current system status.
1.Select the desired monitor. (Refer to p. 90 Monitor Selection.)
2.Press the button 9 while holding down the OSD button. "OSD" will appear on the LED display, and the SYSTEM STATUS table will appear on the active monitor as shown in the figure.
|
| SYSTEM STATUS |
|
| |
MON | CAM | MODE | KB | OPE | PRI |
1 | 01 | T01 | K1 | 1 | 30 |
2 | 02 | SPOT | K2 | 2 | 2 |
3 | 04 | ALARM | K4 | 4 | 1 |
4 | 16 | CAM | PC | 30 | 1 |
F1 | ACK | RESET |
|
|
|
|
CAM SETUP | SUSPEND | ALL RESET |
|
|
| CALL |
|
|
|
|
|
| |
F2 | GROUP SEQ | TOUR SEQ | T&D | CAM ID | EVENT | PRESET |
INDEX | REW/FF | STILL | AUX1 OFF | AUX1 ON | PROGRAM | |
|
|
|
|
|
| PRESET |
| PREV | NEXT | MON STATUS | ALL |
|
|
| STEP |
| AUX2 OFF | AUX2 ON | AUTO PAN | |
RECORDER |
|
| ||||
STOP |
| PAUSE | ALM H | VLD H | SYS S | CAM FUNC |
|
|
|
|
|
| |
STOP | PLAY | PAUSE | SEQUENCE | DEF OFF | DEF ON |
|
| OSD |
| MON (ESC) |
| CAM (SET) | CLEAR |
SETUP |
| SHIFT | MON LOCK | MULTI SCREEN SEL | WIPER | LOG OUT |
The columns in the table indicate the states as shown in the figure.
MON: | Monitor number |
CAM: | Camera number |
| No number indicates no camera is |
| selected. |
MODE: | Lists the display mode on the moni- |
| tors. |
SPOT: | Spot mode |
Tnn: | Tour Sequence mode (nn is the tour |
| sequence number.) |
SET: | |
ALARM: Alarm Active mode | |
ACK: | Alarm ACK mode |
VLD H: | VLD History Table |
ALM H: | Alarm History Table |
SYS S: | System Status Table |
KB: | Lists the system controller number or |
| PC. |
OPE: | Lists the operator number |
PRI: | Lists the priority number |
3. To exit from the mode, press the CLEAR button.