Page 616 of 894 NT8D15 E&M Trunk card

Note: In Cabinet systems equipped with Meridian Mail, the Universal

Trunk line card cannot be installed in slot 10 of the main cabinet.

The NT8D15 E&M trunk card supports the following types of trunks:

2-wire E&M Type I signaling trunks

two-wire dial repeating trunks

two or four wire tie trunks

4-wire E&M trunks:

Type I or Type II signaling

duplex (DX) signaling

paging (PAG) trunks

Type I signaling uses two signaling wires plus ground. Type II and DX signaling uses two pairs of signaling wires. Most electronic switching systems use Type II signaling.

Table 191 lists the signaling and trunk types supported by the NT8D15 E&M trunk card.

Table 191

Trunk and signaling matrix

 

 

 

 

 

 

Trunk types

 

Signaling

 

 

 

 

 

 

 

 

RLM/RLR

 

TIE

 

PAG

CSA/CAA/CAM

 

 

 

 

 

 

 

 

 

 

 

 

 

2-wire E&M

 

Yes

 

Yes

 

Yes

Yes

 

 

 

 

 

 

 

 

4-wire E&M

 

Yes

 

Yes

 

No

Yes

 

 

 

 

 

 

 

 

 

Legend:

 

 

 

 

 

 

 

 

RLM

Release Link Main

 

 

 

 

 

 

RLR

Release Link Remote

 

 

 

 

CSA

Common Control Switching Arrangement

 

 

 

 

CAA

Common Control Switching Arrangement with Automatic Number Identification (ANI)

CAM

Centralized Automatic Message Accounting (CAMA) trunk

 

 

 

 

 

 

 

 

 

 

553-3001-211 Standard 2.00 September 2004

Page 616
Image 616
Nortel Networks 553-3001-211 manual Trunk and signaling matrix Trunk types Signaling, Rlm/Rlr Tie Pag Csa/Caa/Cam