Figure 116

Ground start call states – incoming call from CO/FX/WATS

System (near) end

CO / FX / WATS (far) end

Tip open,

battery on ring

Ground on tip,

battery on ring

High-resistance loop

Low-resistance loop

 

Near end

 

Idle

disconnects

 

 

 

 

 

far end

 

Far end

disconnects

 

disconnects

first

 

Near end

 

 

disconnects

 

 

first (Note 2)

 

 

 

Near end

 

Ringing

answers,

 

ringing is

 

 

Far end

Assignment

removed

originates

to loop key

(Note 1)

Note 1: The far end may reverse battery and ground upon receipt of attendant answer.

Note 2: The near end provides a high-impedance (>150k ohms) disconnect signal of at least 50 ms before reconnecting the ground detector.

553-AAA1133

A trunk identified as possibly reverse-wired is switched by the software to loop start processing after the second ring. This switching takes place on a call-by-call basis. Thus, if a previously correctly wired trunk becomes reverse-wired, the next incoming call is marked as possibly reverse-wired and the threshold count begins.

If the threshold count exceeds its limit, an error message is printed and the trunk is registered as “positively reverse wired.” Once identified as positively reverse wired, the call is presented continuously from the first ring. When a