Page 724 of 894 NTAK20 Clock Controller daughterboard

Note: The card is restricted to slots 1 through 3 in EMC- type cabinets (such as NAK11Dx and NTAK11Fx cabinets). It will not work in slots 4 through 10 in these cabinets.

The NTAK20 clock controller card can support 1.5 Mb, 2.0 Mb, and 2.56 Mb clock recovery rates.

IMPORTANT!

Each MG 1000S that has a digital trunk must have a clock controller clocked to an external reference clock.

If an IP Expansion multi-cabinet system is equipped with digital trunk cards, it is mandatory that at least one trunk card is placed in the Main cabinet.

Note: Clocking slips can occur between MG 1000S systems that are clocked from different COs, if the COs are not synchronized. The slips can degrade voice quality.

The clock controller circuitry synchronizes the system to an external reference clock and generates and distributes the clock to the system. The system can function either as a slave to an external clock or as a clocking master. The NTAK20AD version of the clock controller meets the AT&T Stratum 3 and Bell Canada Node Category D specifications. The NTAK20BD version meets CCITT Stratum 4 specifications.

The NTAK20 card performs the following functions:

phase lock to a reference, generation of the 10.24 Mhz system clock, and distribution of the clock to the CPU through the backplane

accept one primary and one secondary reference

primary-to-secondary switchover and auto-recovery

chatter prevention due to repeated switching

error-burst detection and correction, holdover, and free running capabilities

communication with software

553-3001-211 Standard 2.00 September 2004

Page 724
Image 724
Nortel Networks 553-3001-211 manual 724 of 894 NTAK20 Clock Controller daughterboard