Page 220 of 894 NT5D11 and NT5D14 Lineside T1 Interface cards

Configuring parameters

The MMI has been designed with default settings so that no configuration is necessary. However, it can be configured to suit a specific environment.

Set Time

Before configuring the MMI, login to the system and enter the current time. Do this by typing in the Set Time (S T) command set. The MMI will then display the time it has registered. Enter a new time or press “Enter” to leave it unchanged. The time is entered in the “hh:mm:ss” military time format.

Set Date

The current date must be set. Do this by typing in the Set Date (S D) command set. MMI will then display the date it has registered. Enter a new date or press “Enter” to leave it unchanged. The date is entered in the “mm/dd/yy” format.

Alarm parameters

The Set Alarm (S A) command set establishes the parameters by which an alarm is activated, and its duration. There are three alarm activation levels:

Alarm Level 0 (AL0) consists of activity with an error threshold below the AL1 setting. This is a satisfactory condition and no alarm is activated.

Alarm Level 1 (AL1) consists of activity with an error threshold above the AL1 setting but below AL2 setting. This is a minor unsatisfactory condition. In this situation, the external alarm hardware will be activated by closing the normally open contact, the RED ALARM LED on the faceplate will light, and an alarm message will be created in the alarm log and the MMI terminal.

Alarm Level 2 (AL2) consists of activity with an error threshold above the AL2 setting. This is an unsatisfactory condition. In this situation, the external alarm hardware will be activated by closing the normally open contact, the RED ALARM LED on the faceplate will light, an alarm message will be created in the alarm log and the MMI terminal, the lineside T1 card will enter line processing mode, and a yellow alarm message will be sent to the CPE/CSU. Line processing will send the CS 1000S, CS 1000M, and Meridian 1 either all “on-hook” or all “off-hook” signals, depending on the dip switch setting of the card.

553-3001-211 Standard 2.00 September 2004