Page 172 of 894 NT1R20 Off-Premise Station Analog Line card

Configuring the OPS analog line card

The line type, terminating impedance, and balance network configuration for each unit on the card is selected by software service change entries at the system terminal and by jumper strap settings on the card.

Jumper strap settings

Each line interface unit on the card is equipped with two jumper blocks that are used to select the proper loop current depending upon loop length. See Table 70.

For units connected to loops of 460 to 2300 ohms, both jumper blocks for that unit must have jumper blocks installed. For loops that are 460 ohms or less, jumper blocks are not installed. Figure 24 on page 174 shows the location of the jumper blocks on the OPS analog line card.

Table 70

OPS analog line card – configuration (Part 1 of 2)

Application

On-premise station (ONS)

 

Off-premise station (OPS)

 

 

 

 

 

 

 

 

Class of Service

 

ONP

 

 

 

OPX

 

(CLS) (Note 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loop resistance

 

0–460

 

 

 

0–2300 (Note 2)

 

(ohms)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Jumper strap

Both JX.0 and JX.1

 

Both JX.0 and JX.1

Both JX.0 and JX.1

setting (Note 6)

off

 

 

 

off

 

 

on

 

 

 

 

 

 

 

 

 

 

 

Loop loss (dB)

0–1.5

>0–3.0

 

>2.5–3.0

0–1.5

 

>1.5–2.5

>2.5–4.5

>4.5–15

(Note 3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIMP

600

600

 

600

600

 

600

600

600

(Notes 1, 4)

ohms

ohms

 

ohms

ohms

 

ohms

ohms

ohms

 

 

 

 

 

 

 

 

 

 

BIMP

600

3COM

 

3CM2

600

 

3COM

3CM2

3CM2

(Notes 1, 4)

ohms

 

 

 

ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

553-3001-211 Standard 2.00 September 2004

Page 172
Image 172