Page 196 of 894 NT5D11 and NT5D14 Lineside T1 Interface cards

cabled directly into the MMI terminal or modem; select the slave setting if this card is cabled to another lineside T1 card in a daisy chain.

Tables 75 through 78 describes the proper dip switch settings for each type of T1 link. After the card has been installed, the MMI displays the DIP switch settings the command Display Configuration is used. See “Man-Machine T1 maintenance interface software” on page 213 for details on how to invoke this command.

Table 75

Lineside T1 card—T1 Switch 1 (S1) dip switch settings

Dip Switch

 

 

Number

Characteristic

Selection

 

 

 

1

MMI port speed selection

On = 1200 baud

 

 

Off = 2400 baud

2

T1 signaling

On = Ground start

 

 

Off = Loop start

3–6

XPEC Address for the lineside T1 card

See Table 76

7

Not Used

Leave Off

8

Reserved for SL-100 use

Leave Off

 

 

 

Table 76

Lineside T1 card – XPEC address dip switch settings (Switch S1, positions 3 – 6) (Part 1 of 2)

XPEC

S1 Switch

S1 Switch

S1 Switch

S1 Switch

Address

Position 3

Position 4

Position 5

Position 6

 

 

 

 

 

00

Off

Off

Off

Off

01

Off

Off

Off

On

02

Off

Off

On

Off

03

Off

Off

On

On

04

Off

On

Off

Off

 

 

 

 

 

553-3001-211 Standard 2.00 September 2004