Page 502 of 894 NT7D16 Data Access card

Backplane pinout and signaling

Two 40-pin, and two 20-pin edge connectors connect the card to the backplane. The detailed pinout configurations are listed in Tables 165 and 166.

Table 165

RS-232-C and RS-422 pinouts for first three DAC ports (Part 1 of 2)

 

I/O cable

 

 

RS-232-C

 

 

 

 

 

 

 

 

 

 

 

 

Pair

 

 

 

RS-422

Patch pair or

Pair

Pin

color

Unit no.

Signal

Pin no.

Signal

octopus

 

 

 

 

 

 

 

 

1T

26

W-BL

UNIT 0

TD0

2

RDA0

 

 

 

 

 

 

 

 

 

1R

1

BL-W

 

RD0

3

RDB0

 

 

 

 

 

 

 

 

 

2T

27

W-O

 

DTR0

20

SDA0

 

 

 

 

 

 

 

 

 

2R

2

O-W

 

GND0

7

SDB0

Connector

 

 

 

 

 

 

 

 

3T

28

W-G

 

DCD0

8

 

1

 

 

 

 

 

 

 

 

3R

3

G-W

 

DSR0

6

 

 

 

 

 

 

 

 

 

 

4T

29

W-BR

 

RI0

22

 

 

 

 

 

 

 

 

 

 

4R

4

BR-W

 

CTS0

5

 

 

 

 

 

 

 

 

 

 

5T

20

W-S

UNIT 1

TD1

2

RDA1

 

 

 

 

 

 

 

 

 

5R

5

S-W

 

RD1

3

RDB1

 

 

 

 

 

 

 

 

 

6T

31

R-BL

 

DTR1

20

SDA1

 

 

 

 

 

 

 

 

 

6R

6

BL-R

 

GND1

7

SDB1

Connector

 

 

 

 

 

 

 

 

7T

32

R-O

 

DCD1

8

 

2

 

 

 

 

 

 

 

 

Note 1: The RS-232 pinout follows the standard set by the QPC723 RILC.

Note 2: The RS-422 pinout follows the standard set by the QPC430 AILC (first pair: Receive

Data; second pair: Send Data). Receive and Send are designated with reference to the DTE; therefore, they must be turned over in the cross-connect since most DTE have first pair as Send Data and second pair as Receive Data.

553-3001-211 Standard 2.00 September 2004