Page 824 of 894 NTRB21 DTI/PRI/DCH TMDI card

Cross-connect – Level 1 (DSX-1), or LD-1. Equalizers are switch selectable through dip-switches. The settings are shown in Table 259.

Table 259

NTRB21 switch settings

 

 

Switch Setting

 

 

 

 

 

 

Distance to Digital

1

2

3

4

Cross-Connect

DCH F/W

(LEN 0)

(LEN 1)

(LEN 2)

 

 

 

 

 

0 - 133 feet

Off

Off

Off

On

 

 

 

 

 

133 - 266 feet

Off

On

On

Off

 

 

 

 

 

266 - 399 feet

Off

Off

On

Off

 

 

 

 

 

399 - 533 feet

Off

On

Off

Off

 

 

 

 

 

533 - 655 feet

Off

Off

Off

Off

 

 

 

 

 

Receiver

The receiver extracts data and clock from an incoming data stream and outputs clock and synchronized data. At worst case DSX-1 signal levels, the line receiver operates correctly with up to 655 feet of ABAM cable between the card and the external DS-1 signal source.

553-3001-211 Standard 2.00 September 2004

Page 824
Image 824
Nortel Networks 553-3001-211 manual 824 of 894 NTRB21 DTI/PRI/DCH Tmdi card