NT5D11 and NT5D14 Lineside T1 Interface cards Page 231 of 894
Circuit Card Description and Installation
Test 2, external loopback, assumes an external loopback is applied to the T1
link. Test data is generated and received by the lineside T1 card on all
timeslots. If test 1 passes but test 2 fails, it indicates that the T1 link is
defective between the lineside T1 card and the external loopback location. If
test 1 was not run and test 2 fails, the T1 link or the lineside T1 card could be
defective. To isolate the failure to the T1 link, tests 1 and 2 must be run in
tandem. Figure 32 demonstrates how an external loopback is applied to the
T1 link.
Test 3, network loopback, loops the received T1 data back toward the CPE
equipment. No test data is generated or received by the lineside T1 card. If
test 2 passes but test 3 fails, it indicates that the CPE device is defective. If
test 2 was not run and test 3 fails, the T1 link or the CPE device could be
defective. To isolate the failure to the CPE device, tests 2 and 3 must be run
Figure 31
MMI local loopback test
Figure 32
MMI external loopback test
T-1 link
Line side
T-1
interface
card
Customer
premise
equipment
(CPE)
Common
Equipment
System
External
network T-1 link
553-AAA1120
T-1 link
Line side
T-1
interface
card
Customer
premise
equipment
(CPE)
Common
Equipment
System
External
network T-1 link
553-AAA1121