Page 162 of 894 NT1R20 Off-Premise Station Analog Line card

See Software Input/Output: Administration (553-3001-311) for LD 10

service change instructions.

Table 62

OPS analog line card configuration

Application

On-premise station (ONS)

 

 

Off-premise station (OPS)

 

 

 

 

 

 

 

 

 

 

 

Class of service

 

 

ONS

 

 

 

 

OPS

 

 

 

 

 

 

 

 

 

 

 

 

Loop resistance

 

0 - 460 ohm

 

 

 

 

0 - 2300 ohm

 

 

 

 

 

 

 

 

Jumper strap

Both JX. 0 and JX 1 off

 

Both JX. 0 and JX.

Both JX. 0 and JX.

settingb

 

 

 

 

 

 

 

1 off

 

1 on

Loop loss dBc

0-1.5

 

>1.5-2.

 

>2.5-3.

 

0-1.5

 

>1.5-2.

>2.5-4.

>4.5-15

 

 

 

5

 

0

 

 

 

5

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIMP

600

 

600

 

600

 

600

 

600

600

 

600

 

ohm

 

ohm

 

ohm

 

ohm

 

ohm

ohm

 

ohm

 

 

 

 

 

 

 

 

 

 

 

 

 

BIMP

600

 

3COM

 

3CM2

 

600

 

3COM

3CM2

 

3CM2

 

ohm

 

 

 

 

 

ohm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gain treatment e

 

 

 

 

No

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

a. Configured in the Analog (500/2500-type) Telephone Administration program (LD 10).

b. Jumper strap settings JX 0 and JX. 1 apply to all eight units; “X” indicates the unit number, 0-7. “OFF” indicates that a jumper strap is not installed across both pins on a jumper block. Store unused straps on the OPS analog line card by installing them on a single jumper pin.

c. Loss of untreated (no gain devices) metallic line facility. Upper loss limits correspond to loop resistance ranges for 26 AWG wire.

d. Default software impedance settings are:

ONS CLSOPS CLS TIMP:600 ohm600 ohm BIMP:600 ohm3COM2

e. Gain treatment, such as a voice frequency repeater (VFR) is required to limit the actual OPS loop loss to 4.5 dB, maximum. VFR treatment of metallic loops having untreated loss greater than 15dB (equivalent to a maximum signaling range of 2300 ohm on 26 AWG wire) is not recommended.

553-3001-211 Standard 2.00 September 2004

Page 162
Image 162
Nortel Networks 553-3001-211 manual Ons Ops, 3COM