Note 2:

Page 604 of 894 NT8D14 Universal Trunk card

Table 185

Jumper strap settings – factory standard (NT8D14BA, NT8D14BB)

 

 

Jumper strap settings (Note 1)

 

 

 

 

 

 

Trunk types

Loop length

 

 

 

J4.X

J1.X

J2.X

J3.X

(Note 2)

 

 

 

 

 

 

 

CO/FX/WATS

0–1524 m (5000 ft.)

Off

Off

1–2

1–2

 

 

 

 

 

 

2-way TIE (LDR)

 

 

 

 

 

 

 

 

 

 

 

2-way TIE (OAID)

 

 

 

 

 

 

 

 

 

 

 

DID

0–600 ohms

Off

Off

1–2

1–2

 

 

 

 

 

 

RAN: continuous

Not applicable: RAN

Off

Off

1–2

1–2

operation mode

and paging trunks

 

 

 

 

 

should not leave the

 

 

 

 

Paging

 

 

 

 

building.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1: Jumper strap settings J1.X, J2.X, J3.X, and J4.X apply to all eight units; “X” indicates the unit number, 0–7. “Off” indicates that no jumper strap is installed on a jumper block. Store unused straps on the universal trunk card by installing them on a single jumper pin as shown below.

For the NT8D14BB card, J4.X is not provided on the card. The J4.X jumper setting specified in Table 185 does not apply.

Jumper strap

Jumper pin

Jumper block

553-6317

553-3001-211 Standard 2.00 September 2004

Page 604
Image 604
Nortel Networks 553-3001-211 manual 604 of 894 NT8D14 Universal Trunk card