QPC841 Quad Serial Data Interface card Page 869 of 894

Software service changes

Once the QPC841 QSDI card has been installed in the system, the system software needs to be configured to recognize it. This is done using the Configuration Record program LD 17. Instructions for running the Configuration Record program are found in Software Input/Output: Administration (553-3001-311).

Some of the prompts that are commonly used when running the Configuration Record program LD 17 are shown in LD 17 – Serial port configuration parameters. These parameters must be set for each port that is being used.

LD 17 – Serial port configuration parameters.

Prompt

Response

Description

 

 

 

REQ:

CHG

Change configuration.

TYPE:

CFN

Configuration type.

IOTB

YES

Change input/output devices.

ADAN

NEW TTY x

Define a new system terminal (printer) port as device x, where

 

NEW PRT x

x = 0 to 15.

 

 

CDNO

1-16

Use the QSDI card number to keep track of all ports.

DENS

DDEN

Double density SDI paddle board.

USER

xxx

Enter the user of port x. The values that can be entered

 

 

depend on the software being used. See Software Input/

 

 

Output: Administration (553-3001-311) for details.

XSM

NO YES

Port is used for the system monitor.

 

 

 

Circuit Card Description and Installation