Nortel Networks 553-3001-211 manual Display Performance D P screen

Models: 553-3001-211

1 896
Download 896 pages 29.89 Kb
Page 293
Image 293

NT5D33 and NT5D34 Lineside E1 Interface cards Page 293 of 894

Loss-of-frame seconds are seconds in which loss-of-frame or loss-of-signal conditions have existed for three consecutive seconds.

Frame slip seconds are seconds in which one or more frame slips occur.

The MMI also maintains an overall error counter which is the sum of all errors counted for the performance criteria listed above. The error counter can only be cleared by entering the Clear Error (C E) command. It stops counting at 65,000. The error counter provides an easy method to determine if an alarm condition has been corrected. Clear the error counter, wait a few minutes, and display the performance to see if any errors have occurred since the counter was cleared.

The MMI display reports on these performance counters through the Display Performance (D P) or the Display History (D H) commands.

Display Performance

Entering the Display Performance (D P) command displays performance counters for the past hour. A screen similar to Figure 52 will appear.

Figure 52

Display Performance (D P) screen

 

 

LEI E1 Interface Performance Log

 

 

 

 

3/03/95 1:37 PM

 

Data for the past 37 Minutes

 

 

 

Errored

Bursty

Unavailable

Loss Frame

Frame Slip

Error

Seconds

Seconds

Seconds

Seconds

Seconds

Counter

2263

0

2263

2263

352

321

Each column, except the error counter, indicates the number of errors in the current hour and is reset to zero every hour on the hour. Just before the performance counters are reset to zero, the values are put into the history log.

The error counter indicates the number of errors since the error counter was cleared.