NT8D41AA Serial Data Interface Paddle Board Page 661 of 894

Option switch settings

Address

Address select switch SW4 and logic on the card always address the two UARTs using a pair of addresses: 0 and 1, 2 and 3 through 15 and 16. The settings for this switch are shown in Table 207.

Table 207

SDI paddle board address switch settings

Address

 

Switch SW4

 

 

 

 

 

 

 

Port 1

Port 2

1

2

3

4

 

 

 

 

 

 

0

1

off

on

on

on

2

3

off

on

on

off

4

5

off

on

off

on

6

7

off

on

off

off

8

9

off

off

on

on

10

11

off

off

on

off

12

13

off

off

off

on

14

15

off

off

off

off

 

 

 

 

 

 

Baud rate

Switches SW2 and SW3 determine the baud rate for each individual port. The settings for these switches are shown in Table 208 on page 662.