Page 784 of 894 NTCK16 Generic Central Office Trunk cards

Electrical specifications

Power requirements

Table 251 shows the power requirements for the NTCK16AX and

NTCK16BX generic Central Office trunk cards.

Table 251

NTCK16 circuit card power requirements

Voltage

Idle Current

Active current

 

 

 

+15.0 V dc

170 ma

330 ma

(See 1)

 

 

-15.0 V dc

170 ma

249 ma

(See 1)

 

 

+8.5 V dc

101 ma

100 ma

(See 2)

 

 

+5.0 V dc

160 ma

322 ma

 

 

 

Note 1: Analog circuitry is powered with +/-12 V generated from +/-15 V. The maximum current imbalance between the +/-15 V rails is 100 ma per circuit pack.

Note 2: 8.5V is regulated to give 5 V.

Environmental specifications

Table 252 lists the environmental specifications of the NTCK16AX and

NTCK16BX generic Central Office trunk cards.

Table 252

NTCK16 circuit card environmental specifications (Part 1 of 2)

Parameter

Specifications

 

 

Operating temperature

10 to 45 degrees C

Operating humidity

20 to 80% RH (non-condensing)

 

 

553-3001-211 Standard 2.00 September 2004

Page 784
Image 784
Nortel Networks 553-3001-211 manual 784 of 894 NTCK16 Generic Central Office Trunk cards