Table 33

NT8D14 vintages BA/BB trunk types—termination impedance and balance network (Part 2 of 2)

 

Terminating

Balance network for loop lengths (Note 2)

 

 

 

 

 

 

 

 

Trunk types

impedance

Zero–915 m

915–1524 m

> 1524 m

(Note 1)

(zero–3000 ft)

(3000–5000 ft)

(> 5000 ft)

 

 

 

 

 

 

2-way tie (OAID)

600 or 900

600 ohms

3COM1

3COM2

 

ohms

 

 

 

 

 

 

 

 

DID (loop < 600

600 or 900

600 ohms

3COM1

3COM2

ohms)

ohms

 

 

 

 

 

 

 

 

DID (loop Š 600

600 or 900

600 ohms

N/A

3COM2

ohms)

ohms

 

 

 

 

 

 

 

 

RAN: continuous

600 or 900

600 or 900 ohms

N/A

N/A

operation mode

ohms

 

 

 

 

 

 

 

 

Paging

600 ohms

600 ohms

N/A

N/A

 

 

 

 

 

Note 1: The terminating impedance of each trunk unit is software selectable in LD 14 and should match the nominal impedance of the connecting equipment.

Note 2: The balance network of each trunk unit is software selectable between resistive 600 or 900 ohms or 3COM and is jumper selectable between 3COM1 and 3COM2.