NT6D80 MSDL card Page 405 of 894

Manually controlled maintenance

Use manual maintenance commands found in the following programs to enable, disable, reset, get the status of, and perform self-tests on the MSDL card:

Input/Output Diagnostic Program LD 37

Program LD 42

Link Diagnostic Program LD 48

PRI D-channel Diagnostic Program LD 96

For a complete discussion of these programs, refer to Software Input/Output: Administration (553-3001-311).

Note 1: Enter commands after the dot (.) prompt.

Note 2: The “x” in the commands below represents the DNUM value of the card number.

Enabling the MSDL

Enter ENL MSDL x to enable the MSDL manually. If the MSDL base code has not been previously downloaded or if the card version is different from the one on the system disk, the software is downloaded and the card is enabled.

To force software download and enable the card, enter ENL MSDL x FDL. This command forces the download of the MSDL base code and the configured peripheral software even if it is already resident on the card. The card is then enabled.

To enable a disabled MSDL and its ports, enter ENL MSDL x ALL. This command downloads all peripheral software (if required) and enables any configured ports on the card. This command can be issued to enable some manually disabled ports on an already enabled MSDL.