Page 96 of 894 Acceptance tests

For other than an NT8D17 Conference/TDS card, enter:

ENLL loop

4Test the TDS loop:

TDS loop

If the system response is other than OK, see the Software Input/Output: Administration (553-3001-311) to analyze the messages.

5End the session in LD 34:

****

6Using a maintenance telephone, log into the system.

See “Communicating with the Meridian 1” in the Software Input/Output: Administration (553-3001-311) for details on accessing the system using a maintenance telephone.

7From the maintenance telephone, enter:

LD#34##

To test outpulsers and channels for the TDS loop, see Table 12 on page 96 for a sample of the input commands used with the maintenance telephone. See the Software Input/Output: Administration (553-3001-311) for all tones that can be tested.

8Exit LD 34 from the maintenance telephone:

****

Table 12

 

 

End of Procedure

 

 

 

 

 

 

 

 

TDS tone tests

 

 

 

 

 

 

 

 

 

 

 

 

Dial pad

 

 

 

Input command

 

equivalent

Description

 

 

 

 

BSY#loop##

 

279#loop##

Provides busy tone from TDS loop specified.

 

 

 

 

C##

 

2##

Removes any active tone.

 

 

 

 

DIA#loop##

 

342#loop##

Provides dial tone from TDS loop specified.

 

 

 

 

OVF#loop##

 

683#loop##

Provides overflow tone from TDS loop specified.

 

 

 

 

RBK#loop##

 

725#loop##

Provides ringback tone from TDS loop specified.

 

 

 

 

 

 

553-3001-211 Standard 2.00 September 2004

Page 96
Image 96
Nortel Networks 553-3001-211 manual TDS loop, LD#34##