Page 354 of 894 NT5D97 Dual-port DTI2/PRI2 card

Port 0 of the NTBK51AA can only be defined to work with Loop 0 of the NT5D97 DDP2 card, and Port 1 of the NTBK51AA can only be defined to work with Loop 1 of the NT5D97. This relationship must be reflected when configuring a new DCH in LD 17 (in response to the DCHL prompt, enter either 0 or 1 when specifying the loop number used by the DCH).

You cannot define one of the DDP2 loops for the NTBK51AA DDCH, and the other loop for the NT6D11AF/NT5K75AA/NT5K35AA DCH card or the NT6D80 MSDL.

When configuring the NT5D97 DDP2 in DTI2 outgoing dial pulse mode, a Digit Outpulsing patch is required.

Testability and diagnostics

The DDP2 card supports testing and maintenance functions through the following procedures:

Selftest upon power up or reset

Signalling test performed in the LD 30

Loopback tests, self tests, and continuity tests performed by LD 60 and LD 45

The D-Channel (DCH, MSDL, DDCH) maintenance is supported by LD 96.

Note: The MSDL selftest is not applicable to the NTBK51AA D-Channel daughterboard.

553-3001-211 Standard 2.00 September 2004

Page 354
Image 354
Nortel Networks 553-3001-211 manual Testability and diagnostics