Page 650 of 894 NT8D15 E&M Trunk card

trunks. The class of service determines the operation of the switchable pads contained in each unit. They are assigned as follows:

TRC for a 2-wire non-VNL trunk facility with a loss of greater than

2 dB, or for which impedance compensation is provided, or for a 4-wire non-VNL facility.

NTC for a 2-wire, non-VNL trunk facility with a loss of less than 2 dB, or when impedance compensation is not provided.

See Table 204 for the pad switching control for the various through connections and the actual port-to-port loss introduced for connections between the E&M trunk card and any other IPE port designated as Port B.

Figure 152 on page 651 shows the pad switching orientation.

Table 204

Pad switching algorithm

 

Port B pads

E&M Trunk Pads

Port-to-port loss (dB)

 

 

 

 

 

 

 

 

Transmit

Receive

Transmit

Receive

Port B to

E&M to

Port B

D to A

A to D

D to A

A to D

E&M

Port B

 

 

 

 

 

 

 

IPE line

N/A

N/A

Out

In

2.5

3.5

Universal trunk

Out

Out

In

In

0

0

(TRC)

 

 

 

 

 

 

IPE TIE (VNL)

In

Out

In

Out

0

0

Note: Transmit and receive designations are from and to the system. Transmit is from the system to the external facility (digital-to-analog direction in the E&M trunk card). Receive is to the system from the external facility (analog-to-digital direction in the E&M trunk card).