Page 550 of 894 NT8D09 Analog Message Waiting Line card

the system for port-to-port loss. See Software Input/Output: Administration

(553-3001-311) for LD 97 service change instructions.

Table 178

Transmission Profile Changes

Vintage

A/D convertor gain

D/A convertor gain

 

 

 

Previous to AK

–3.5 dB

–2.5 dB

AK and later

–3.5 dB

–0.5 dB

 

 

 

553-3001-211 Standard 2.00 September 2004