Page 286 of 894 NT5D33 and NT5D34 Lineside E1 Interface cards

Figure 48

Set Mode (S M): Table screen

LEI:>S M

1)Default

2)Table

Hit <CR> to accept current value or type in a new one.

Current Mode : 1 New Mode : 2 Signaling Bits set to Table.

Incoming and outgoing calls are in reference to the CPE.

All ABCD bits are

with respect

to

SENDing

from LEI/M1

to CPE

or RECEIVing

from

CPE

to

LEI/M1.

 

 

 

 

Please

enter

new

ABCD

bits or

hit

<CR>

to

accept. You

may

enter

2 or 4

values.

If

only

2 values

are entered, the A and

B bits

will

be copied

to

the C

and

D bits.

 

 

IDLE SEND: Current: 0000 New: 0101

IDLE SEND bits changed to: 0101

IDLE RECEIVE: Current: 0101 New:

IDLE RECEIVE bits unchanged.

BLOCKING RECEIVE enabled? (Y/N): N

BLOCKING RECEIVE is disabled.

Incoming call RINGER-ON SEND: Current: 0000 New: Incoming call RINGER-ON SEND bits not changed.

Incoming call RINGER-OFF SEND: Current: 0101 New: 0101 Incoming call RINGER-OFF SEND bits not changed.

Incoming call OFFHOOK RECEIVE: Current: 1111 New: 11 Incoming call OFFHOOK RECEIVE bits not changed.

Incoming call CONNECTED SEND: Current: 0101 New: Incoming call CONNECTED SEND bits not changed.

Incoming call (Far End) DISCONNECT SEND: Current: 1111 New: Incoming call (Far End) DISCONNECT SEND bits not changed.

Incoming call (CPE) DISCONNECT RECEIVE: Current: 0101 New: Incoming call (CPE) DISCONNECT RECEIVE not changed.

unable to accept new calls. Set this value to N if this state is not needed. If this value is not set to N, then dip switch #2 position 6 will determine whether off-hook or on-hook is sent to the M1/SL100 when this state is entered. See Table 94 on page 258.