NT8D15 E&M Trunk card Page 637 of 894

Table 193 and Table 194 show call-connection and take-down sequencing for DX signaling. Table 195 on page 638 and Table 196 on page 639 show sequencing where the E&M trunk card is used in a tandem PBX.

Table 193

DX signaling – outgoing calls with originating party release

 

Current in

State of trunk

Condition

signaling lead

detector

 

 

 

Idle

No current flow

High

Seizure

Current flow

High

(dial tone from far-end: far-end ready for digits)

 

 

Digits

Current flow interrupted

High

 

for each pulse

 

Far-end answers

No current flow

Low

Far-end on hook first

Current flow

High

Network taken down and trunk idled when

No current flow

High

near-end goes on hook

 

 

Near-end on hook first, network taken down

Current flow

Low

Far-end on hook, trunk idled

No current flow

High

 

 

 

Table 194

DX signaling – incoming calls with originating party release (Part 1 of 2)

 

Current in

State of trunk

Condition

signaling lead

detector

 

 

 

Idle

No current flow

High

Seizure

Current flow

Low

(dial tone to far-end: near-end ready for digits)

 

 

Digits

Current flow interrupted

Low-high-low

 

for each pulse

for each pulse

Near-end answers

No current flow

Low

 

 

 

Circuit Card Description and Installation

Page 637
Image 637