Page 864 of 894 QPC841 Quad Serial Data Interface card

Table 269

Connector J2 pin assignments (Part 2 of 2)

Pin

 

 

 

 

Number

Port

Signal

Purpose in DTE mode

Purpose in DCE mode

 

 

 

 

 

19

 

GND

Ground

Ground

21

 

CD

Carrier detect (Note 1

Carrier detect (not used)

22

 

DTR

Data terminal ready

Data terminal ready (Note 2))

 

 

 

 

 

Note 1: In DTE mode, the signals CD, DSR, and CTS are tied to +12 volts (through a resistor) to indicate that the QSDI port is always ready to transmit and receive data.

Note 2: In DCE mode, the signals DTR and RTS are tied to +12 volts (through a resistor) to indicate that the QSDI port is always ready to transmit and receive data.

Configuring the QSDI card

Configuring the QSDI card consists of setting these option switches for each serial port:

Port address

Baud rate

DTE/DCE mode

Figure 186 on page 868 shows the location of the option switches on the QSDI card. Instructions for setting these switches are in the section that follows.

Address switch settings

Table 270 on page 865 lists the address switch settings for the QPC841 Quad Serial Data Interface card. The address select jumpers and logic on the card address the UARTs using two pairs of addresses: 0 and 1, 2 and 3, through 15 and 16. The pairs do not need to be consecutive. Switch SW14 is used to