Page 576 of 894 NT8D14 Universal Trunk card

Figure 123

Two-way, loop DR, TIE trunk call connection sequence – incoming call from far-end PBX

A

 

 

Near end

 

Far end

 

B

 

 

 

 

System

 

 

System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

State

 

 

 

Signal/direction

 

 

Remarks

 

 

 

 

 

Ground on tip/

Ground on tip/

 

 

 

 

 

 

Idle

battery on ring

battery on ring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low-resistance loop

 

 

 

 

Trunk seizure

 

 

 

Far end places a low resistance between tip and ring.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Near end detects increase in loop current and makes

 

 

 

 

 

 

 

Address signaling

trunk busy to all outgoing calls.

 

Outpulsing

 

 

 

Far end applies addressing to the trunk in the form of

 

 

 

 

 

 

 

 

 

 

 

Ringback

 

 

 

battery-ground or loop pulsing, or DTMF tones.

 

A rings

 

 

 

Near end detects addressing, alerts terminal A, and

 

Battery on tip/

 

 

 

 

 

 

 

 

 

 

provides ringback tone to far end.

 

2-way voice

ground on ring

 

 

 

When terminal A goes off hook, near end trips ringback

connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tone and provides answer supervision, if required by far

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

end, by reversing battery and ground on tip and ring.

B goes on hook

 

 

 

High-resistance loop

If far end disconnects first, it momentarily opens the loop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and then restores normal battery and ground if no near-

 

 

 

 

 

 

 

 

 

 

 

end answer supervision was provided when call was

 

 

 

 

Ground on tip/

 

 

 

establish-ed. Otherwise, it waits for the near end to

 

 

 

 

 

 

 

restore normal battery and ground.

 

 

 

 

 

battery on ring

 

 

 

Near end detects drop in loop current and restores normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground on tip/

battery and ground if answer supervision was provided.

 

 

 

 

 

 

 

 

Otherwise, terminal A simply hangs up.

 

 

 

Idle

 

 

 

 

battery on ring

If answer supervision was provided, far end restores

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

normal battery and ground when it detects

 

 

 

 

 

 

 

 

 

 

 

 

battery/ground reversal from near end.

 

 

 

 

 

Ground on tip/

 

 

 

 

 

 

 

A goes on hook

battery on ring

 

 

 

If near end disconnects first, normal battery is restored if

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

answer supervision was provided to establish call.

 

 

 

 

 

 

 

 

Ground on tip/

Otherwise, terminal A simply hangs up.

 

 

 

Idle

 

 

 

 

battery on ring

If far end detects battery/ground reversal, it

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

momentarily opens loop and then restores normal

 

 

 

 

 

 

 

 

 

 

 

battery. But, if no answer supervision was provided by

 

 

 

 

 

 

 

 

 

 

 

the near end when the call was established, it cannot

 

 

 

 

 

 

 

 

 

 

 

supply a battery reversal to signal call termination; the

 

 

 

 

 

 

 

 

 

 

 

person at terminal B must recognize end of call and

 

 

 

 

 

 

 

 

 

 

 

hang up, which will then cause the far end to restore

 

 

 

 

 

 

 

 

 

 

 

normal battery.

553-AAA1140

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

553-3001-211 Standard 2.00 September 2004

Page 576
Image 576
Nortel Networks 553-3001-211 manual 576 of 894 NT8D14 Universal Trunk card